Assessment Year | 1989 |
---|---|
Principal Product | WOVEN FABRIC |
NAICS |
n/a
|
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | $10 M to 50M |
# of Employees | 92 |
Plant Area |
n/a
|
Annual Production | 37,500
thousand feet
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $379,243 | 9,477,140 |
kWh
|
$0.040 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,041 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,741 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,521 | $4,413 |
$2,521
63,013
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $670 | $3,438 |
$670
16,706
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,920 | $4,370 |
$5,920
148,007
kWh
|
|
04 | 2.4312: Improve lubrication practices | $550 | - |
$550
13,775
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,380 | - |
$3,380
84,408
kWh
|
|
TOTAL RECOMMENDED | $13,041 | $12,221 |
$13,041
325,909
kWh
|
||
TOTAL IMPLEMENTED | $3,741 | $7,851 |
$3,741
93,494
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs