Assessment Year 1988
Principal Product TEXTILE MACHINERY
NAICS
n/a
SIC 3552: Textile Machinery
Sales Range $10
M
to 50
M
# of Employees 350
Plant Area
n/a
Annual Production 2,400,000
lb
Production Hrs. Annual 4,000
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $286,767 3,898,886
kWh
Natural Gas $56,336 9,174
MMBtu
LPG $12,371 1,740
MMBtu
Coal $43,446 7,589
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,601 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $28,297

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $18,054 $32,379 $18,054
241,208
kWh
-
02 2.4133: Use most efficient type of electric motors $304 $284 $304
4,396
kWh
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $202 - $202
2,931
kWh
-
04 2.1233: Analyze flue gas for proper air/fuel ratio $10,041 $800 - $10,041
-
MMBtu
TOTAL RECOMMENDED $28,601 $33,463 $18,560
248,535
kWh
$10,041
-
MMBtu
TOTAL IMPLEMENTED $28,297 $33,179 $18,256
244,139
kWh
$10,041
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs