Assessment Year | 1988 |
---|---|
Principal Product | DRILL BITS |
NAICS |
n/a
|
SIC | 3545: Cutting Tools, Machine Tool Accessories, and Machinists' Precision Measuring Devices |
Sales Range | $5 M to 10M |
# of Employees | 550 |
Plant Area |
n/a
|
Annual Production | 750,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $843,651 | 16,826,495 |
kWh
|
$0.050 |
Natural Gas | $27,561 | 5,061 |
MMBtu
|
$5.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $95,350 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,945 | $200 |
$2,945
58,910
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $380 | $370 |
$380
8,206
kWh
|
|
03 | 2.7229: Air condition only space necessary | $930 | $840 |
$930
42,204
kWh
|
|
04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $12,120 | $4,685 |
$12,120
550,996
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $472 | $377 |
$472
5,862
kWh
|
|
06 | 2.3191: Use demand controller or load shedder | $66,800 | $45,607 |
$66,800
574,443
kWh
|
|
07 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $11,540 | $32,000 |
$11,540
274,033
kWh
|
|
08 | 2.4133: Use most efficient type of electric motors | $163 | $150 |
$163
3,224
kWh
|
|
TOTAL RECOMMENDED | $95,350 | $84,229 |
$95,350
1,517,878
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs