| Assessment Year | 1992 |
|---|---|
| Principal Product | ZINC DUST & ZINC INGOTS |
| NAICS |
n/a
|
| SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 28,000
lb
|
| Production Hrs. Annual | 5,952
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $337,384 | 6,546,893 |
kWh
|
$0.052 |
| Natural Gas | $287,431 | 140,436 |
MMBtu
|
$2.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $104,963 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $41,170 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2422: Use waste heat from hot flue gases to generate steam | $58,460 | $15,870 | - |
$58,460
-
MMBtu
|
|
| 02 | 2.3191: Use demand controller or load shedder | $18,230 | $6,000 |
$18,230
-
kWh
|
- | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $11,040 | $630 |
$11,040
210,434
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $1,348 | $595 |
$1,348
26,377
kWh
|
- | |
| 05 | 2.6124: Establish equipment maintenance schedule | $6,360 | - |
$6,360
41,911
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,325 | - |
$2,325
45,428
kWh
|
- | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $2,320 | $6,850 |
$2,320
56,565
kWh
|
- | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,305 | $4,080 |
$2,305
45,135
kWh
|
- | |
| 09 | 2.8123: Pay utility bills on time | $1,665 | - |
$1,665
-
kWh
|
- | |
| 10 | 2.7111: Reduce illumination to minimum necessary levels | $910 | - |
$910
14,361
kWh
|
- | |
| TOTAL RECOMMENDED | $104,963 | $34,025 |
$46,503
440,211
kWh
|
$58,460
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $41,170 | $10,710 |
$41,170
357,269
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||