| Assessment Year | 1988 |
|---|---|
| Principal Product | ELECTROMECHANICAL COMPONENTS |
| NAICS |
n/a
|
| SIC | 3625: Relays and Industrial Controls |
| Sales Range | $5 M to 10M |
| # of Employees | 120 |
| Plant Area |
n/a
|
| Annual Production | 2,000,000
pieces
|
| Production Hrs. Annual | 4,990
hrs
|
| Location (State) | Alabama |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $99,201 | 1,320,047 |
kWh
|
$0.075 |
| Natural Gas | $1,686 | 300 |
MMBtu
|
$5.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,921 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,701 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,520 | - |
$2,520
-
kWh
|
|
| 02 | 2.7226: Use computer programs to optimize hvac performance | $3,950 | $1,800 |
$3,950
122,509
kWh
|
|
| 03 | 2.7122: Disconnect ballasts | $210 | $230 |
$210
2,638
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,741 | $21,965 |
$7,741
102,872
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,010 | $2,080 |
$1,010
13,482
kWh
|
|
| 06 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $490 | $500 |
$490
6,448
kWh
|
|
| TOTAL RECOMMENDED | $15,921 | $26,575 |
$15,921
247,949
kWh
|
||
| TOTAL IMPLEMENTED | $14,701 | $24,265 |
$14,701
231,829
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs