Assessment Year | 1988 |
---|---|
Principal Product | ELECTROMECHANICAL COMPONENTS |
NAICS |
n/a
|
SIC | 3625: Relays and Industrial Controls |
Sales Range | $5 M to 10M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 2,000,000
pieces
|
Production Hrs. Annual | 4,990
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $99,201 | 1,320,047 |
kWh
|
$0.075 |
Natural Gas | $1,686 | 300 |
MMBtu
|
$5.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,921 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,701 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,520 | - |
$2,520
-
kWh
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $3,950 | $1,800 |
$3,950
122,509
kWh
|
|
03 | 2.7122: Disconnect ballasts | $210 | $230 |
$210
2,638
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,741 | $21,965 |
$7,741
102,872
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,010 | $2,080 |
$1,010
13,482
kWh
|
|
06 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $490 | $500 |
$490
6,448
kWh
|
|
TOTAL RECOMMENDED | $15,921 | $26,575 |
$15,921
247,949
kWh
|
||
TOTAL IMPLEMENTED | $14,701 | $24,265 |
$14,701
231,829
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs