Assessment Year | 1988 |
---|---|
Principal Product | LATEX PAINT |
NAICS |
n/a
|
SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
Sales Range | $10 M to 50M |
# of Employees | 67 |
Plant Area |
n/a
|
Annual Production | 11,500
Tgal
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $32,841 | 344,959 |
kWh
|
$0.095 |
Natural Gas | $15,326 | 4,096 |
MMBtu
|
$3.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,763 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $4,814 | $20,200 |
$4,814
-
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $1,620 | $1,500 |
$1,620
25,498
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $1,289 | $1,426 |
$1,289
20,223
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,254 | $1,329 |
$1,254
19,637
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $786 | - |
$786
11,137
kWh
|
|
TOTAL RECOMMENDED | $9,763 | $24,455 |
$9,763
76,495
kWh
|
||
TOTAL IMPLEMENTED | $3,329 | $2,755 |
$3,329
50,997
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs