| Assessment Year | 1988 | 
|---|---|
| Principal Product | LATEX PAINT | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products | 
| Sales Range | $10 M  to 50M  | 
    
| # of Employees | 67 | 
| Plant Area | 
                             n/a 
                     | 
    
| Annual Production | 11,500
             
Tgal
 
         | 
    
| Production Hrs. Annual | 5,000
             
hrs
 
         | 
    
| Location (State) | Georgia | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $32,841 | 344,959 | 
             
kWh
 
         | 
        $0.095 | 
| Natural Gas | $15,326 | 4,096 | 
             
MMBtu
 
         | 
        $3.74 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,763 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $3,329 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | 
|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $4,814 | $20,200 | 
                        $4,814
                                                     -
                                 
                                            
kWh
 
                             | 
                                    |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $1,620 | $1,500 | 
                        $1,620
                                                     25,498
                                 
                                            
kWh
 
                             | 
                                    |
| 03 | 2.4133: Use most efficient type of electric motors | $1,289 | $1,426 | 
                        $1,289
                                                     20,223
                                 
                                            
kWh
 
                             | 
                                    |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,254 | $1,329 | 
                        $1,254
                                                     19,637
                                 
                                            
kWh
 
                             | 
                                    |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $786 | - | 
                        $786
                                                     11,137
                                 
                                            
kWh
 
                             | 
                                    |
| TOTAL RECOMMENDED | $9,763 | $24,455 | 
                        $9,763
                                                     76,495
                                 
                                            
kWh
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $3,329 | $2,755 | 
                        $3,329
                                                     50,997
                                 
                                            
kWh
 
                             | 
                                    ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs