Assessment Year | 1988 |
---|---|
Principal Product | ENGINE HEAD GASKETS |
NAICS |
n/a
|
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
n/a
|
Annual Production | 20,000,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $279,754 | 5,211,020 |
kWh
|
$0.054 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,931 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,440 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $360 | $550 |
$360
15,826
kWh
|
|
02 | 2.7314: Reduce ventilation air | $2,230 | $400 |
$2,230
85,873
kWh
|
|
03 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $1,170 | $760 |
$1,170
29,894
kWh
|
|
04 | 2.7123: Keep lamps and reflectors clean | $1,730 | $3,720 |
$1,730
47,186
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $480 | $460 |
$480
20,809
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $111 | $112 |
$111
1,465
kWh
|
|
07 | 2.3191: Use demand controller or load shedder | $5,850 | $400 |
$5,850
-
kWh
|
|
TOTAL RECOMMENDED | $11,931 | $6,402 |
$11,931
201,053
kWh
|
||
TOTAL IMPLEMENTED | $8,440 | $1,350 |
$8,440
101,699
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs