Assessment Year | 1988 |
---|---|
Principal Product | CONTINUOUS BUS. FORMS |
NAICS |
n/a
|
SIC | 2761: Manifold Business Forms |
Sales Range | $5 M to 10M |
# of Employees | 95 |
Plant Area |
n/a
|
Annual Production | 6,600,000
pieces
|
Production Hrs. Annual | 7,280
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,899 | 1,123,681 |
kWh
|
$0.090 |
Natural Gas | $586 | 93 |
MMBtu
|
$6.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,457 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,228 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2522: Isolate hot or cold equipment | $479 | $1,000 |
$479
20,809
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,008 | - |
$1,008
43,962
kWh
|
|
03 | 2.7111: Reduce illumination to minimum necessary levels | $2,170 | $6,600 |
$2,170
32,239
kWh
|
|
04 | 2.7111: Reduce illumination to minimum necessary levels | $50 | - |
$50
2,052
kWh
|
|
05 | 2.3191: Use demand controller or load shedder | $10,750 | $10,300 |
$10,750
-
kWh
|
|
TOTAL RECOMMENDED | $14,457 | $17,900 |
$14,457
99,062
kWh
|
||
TOTAL IMPLEMENTED | $3,228 | $6,600 |
$3,228
78,253
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs