Assessment Year | 1987 |
---|---|
Principal Product | DYED YARN |
NAICS |
n/a
|
SIC | 2269: Finishers of Textiles, Not elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
n/a
|
Annual Production | 1,200,000
lb
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $17,172 | 298,066 |
kWh
|
$0.058 |
Natural Gas | $83,904 | 16,422 |
MMBtu
|
$5.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,011 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,842 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,890 | $250 | - |
$1,890
-
MMBtu
|
|
02 | 2.2136: Install / repair insulation on steam lines | $5,219 | $1,778 | - |
$5,219
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $1,083 | $2,200 | - |
$1,083
-
MMBtu
|
|
04 | 2.5191: Modify dye beck | $3,166 | $1,350 | - |
$3,166
-
MMBtu
|
|
05 | 2.5191: Modify dye beck | $2,902 | $2,300 | - |
$2,902
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $184 | $57 |
$184
3,224
kWh
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $466 | $541 |
$466
8,206
kWh
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,101 | - |
$1,101
19,050
kWh
|
- | |
TOTAL RECOMMENDED | $16,011 | $8,476 |
$1,751
30,480
kWh
|
$14,260
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,842 | $3,919 |
$1,567
27,256
kWh
|
$10,275
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs