Assessment Year | 1987 |
---|---|
Principal Product | METAL CABINETS& DISPLAYS |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,941 | 1,337,046 |
kWh
|
$0.060 |
Natural Gas | $30,095 | 9,253 |
MMBtu
|
$3.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,404 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,622 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7123: Keep lamps and reflectors clean | $1,390 | $1,577 |
$1,390
24,033
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $92 | $40 |
$92
1,465
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,700 | $1,050 |
$1,700
29,308
kWh
|
- | |
04 | 2.2422: Use waste heat from hot flue gases to generate steam | $458 | $3,000 | - |
$458
-
MMBtu
|
|
05 | 2.2531: Re-size charging openings or add movable cover or door | $1,320 | $480 | - |
$1,320
-
MMBtu
|
|
06 | 2.2531: Re-size charging openings or add movable cover or door | $1,440 | $500 | - |
$1,440
-
MMBtu
|
|
07 | 2.8114: Change rate schedules or other changes in utility service | $3,004 | $5,000 |
$3,004
-
kWh
|
- | |
TOTAL RECOMMENDED | $9,404 | $11,647 |
$6,186
54,806
kWh
|
$3,218
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,622 | $3,167 |
$3,182
54,806
kWh
|
$1,440
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs