| Assessment Year | 1986 |
|---|---|
| Principal Product | SPUN CARPET YARN |
| NAICS |
n/a
|
| SIC | 2281: Yarn Spinning Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
n/a
|
| Annual Production | 7,600,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $491,621 | 9,842,908 |
kWh
|
$0.050 |
| Natural Gas | $168,648 | 40,947 |
MMBtu
|
$4.12 |
| Fuel Oil #2 | $5,673 | 1,589 |
MMBtu
|
$3.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $263,636 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $2,170 | $2,356 |
$2,170
43,376
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,783 | $32,572 |
$11,783
235,639
kWh
|
- | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,882 | $2,790 |
$1,882
37,515
kWh
|
- | - | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $10,257 | $1,000 | - |
$9,925
-
MMBtu
|
$332
-
MMBtu
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,970 | - |
$1,970
39,273
kWh
|
- | - | |
| 06 | 2.7226: Use computer programs to optimize hvac performance | $61,200 | $10,000 |
$61,200
1,224,209
kWh
|
- | - | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $37,018 | $91,200 | - |
$35,815
-
MMBtu
|
$1,203
-
MMBtu
|
|
| 08 | 2.4312: Improve lubrication practices | $10,261 | - |
$10,261
205,158
kWh
|
- | - | |
| 09 | 2.1333: Convert combustion equipment to burn oil | $127,095 | $28,000 | - |
$122,961
-
MMBtu
|
$4,134
-
MMBtu
|
|
| TOTAL RECOMMENDED | $263,636 | $167,918 |
$89,266
1,785,170
kWh
|
$168,701
-
MMBtu
|
$5,669
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs