Assessment Year | 1986 |
---|---|
Principal Product | WELDING TORCHES |
NAICS |
n/a
|
SIC | 3549: Metalworking Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 350,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $157,891 | 2,720,399 |
kWh
|
$0.058 |
Natural Gas | $18,198 | 3,228 |
MMBtu
|
$5.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,728 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,700 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7245: Use direct air supply to exhaust hoods | $2,456 | $1,350 |
$690
11,137
kWh
|
$1,766
-
MMBtu
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $5,150 | $22,975 |
$5,150
88,804
kWh
|
- | |
03 | 2.3191: Use demand controller or load shedder | $13,268 | $1,500 |
$13,268
-
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,040 | $15,677 |
$7,040
121,336
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $392 | $863 |
$392
6,741
kWh
|
- | |
06 | 2.2136: Install / repair insulation on steam lines | $422 | $445 | - |
$422
-
MMBtu
|
|
TOTAL RECOMMENDED | $28,728 | $42,810 |
$26,540
228,018
kWh
|
$2,188
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,700 | $18,040 |
$20,700
128,077
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs