Assessment Year | 1985 |
---|---|
Principal Product | LUMBER |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $1 M to 5M |
# of Employees | 25 |
Plant Area |
n/a
|
Annual Production | 5,000
thousand feet
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $39,425 | 347,011 |
kWh
|
$0.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,515 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,515 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $515 | $716 |
$515
4,689
kWh
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,040 | $3,935 |
$2,040
18,757
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,000 | $300 |
$2,000
18,171
kWh
|
|
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,960 | - |
$5,960
-
kWh
|
|
TOTAL RECOMMENDED | $10,515 | $4,951 |
$10,515
41,617
kWh
|
||
TOTAL IMPLEMENTED | $10,515 | $4,951 |
$10,515
41,617
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs