| Assessment Year | 1985 |
|---|---|
| Principal Product | FABRICATED SIGNS |
| NAICS |
n/a
|
| SIC | 3993: Signs and Advertising Specialties |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 1,200
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $54,711 | 676,143 |
kWh
|
$0.081 |
| Natural Gas | $15,857 | 2,631 |
MMBtu
|
$6.03 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,989 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,306 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $308 | $217 |
$308
3,810
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $190 | $323 |
$190
2,345
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,084 | $500 |
$3,084
38,101
kWh
|
- | |
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $375 | $936 |
$(-47.0)
(-586)
kWh
|
$422
-
MMBtu
|
|
| 05 | 2.4322: Use or replace with energy efficient substitutes | $4,032 | $3,200 |
$4,032
49,824
kWh
|
- | |
| TOTAL RECOMMENDED | $7,989 | $5,176 |
$7,567
93,494
kWh
|
$422
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,306 | $4,023 |
$7,306
90,270
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs