| Assessment Year | 1985 |
|---|---|
| Principal Product | MOLD INHIBITOR FOR FEED |
| NAICS |
n/a
|
| SIC | 2879: Pesticides and Agricultural Chemicals, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 19 |
| Plant Area |
n/a
|
| Annual Production | 1,500,000
lb
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $12,374 | 127,784 |
kWh
|
$0.097 |
| Natural Gas | $7,102 | 1,164 |
MMBtu
|
$6.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,070 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $610 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $80 | $152 |
$80
879
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $230 | $302 |
$230
2,345
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $300 | $50 |
$300
2,931
kWh
|
- | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $2,460 | $6,830 | - |
$2,460
-
MMBtu
|
|
| TOTAL RECOMMENDED | $3,070 | $7,334 |
$610
6,155
kWh
|
$2,460
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $610 | $504 |
$610
6,155
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs