Assessment Year | 1985 |
---|---|
Principal Product | COLUMNS & SQUAT TURN POST |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 40,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $18,088 | 186,987 |
kWh
|
$0.097 |
Natural Gas | $3,150 | 542 |
MMBtu
|
$5.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,206 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $860 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $860 | $400 |
$860
8,792
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $122 | $16 |
$122
1,172
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $224 | $275 |
$224
2,345
kWh
|
|
TOTAL RECOMMENDED | $1,206 | $691 |
$1,206
12,309
kWh
|
||
TOTAL IMPLEMENTED | $860 | $400 |
$860
8,792
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs