Assessment Year | 1985 |
---|---|
Principal Product | VALVES |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 1,200,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $37,054 | 490,914 |
kWh
|
$0.075 |
Fuel Oil #2 | $5,068 | 700 |
MMBtu
|
$7.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,752 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,534 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,317 | $500 |
$2,317
30,774
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $940 | $277 |
$940
12,603
kWh
|
- | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $218 | $585 |
$(-32.0)
(-293)
kWh
|
$250
-
MMBtu
|
|
04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $277 | $150 |
$277
3,810
kWh
|
- | |
TOTAL RECOMMENDED | $3,752 | $1,512 |
$3,502
46,894
kWh
|
$250
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,534 | $927 |
$3,534
47,187
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs