Assessment Year | 1985 |
---|---|
Principal Product | RAILCARS |
NAICS |
n/a
|
SIC | 3743: Railroad Equipment |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
n/a
|
Annual Production | 500
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $112,417 | 1,737,984 |
kWh
|
$0.065 |
Natural Gas | $7,878 | 1,750 |
MMBtu
|
$4.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,221 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $780 | $20,000 | - |
$780
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $380 | $175 |
$380
5,862
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $238 | $373 |
$238
3,810
kWh
|
- | |
04 | 2.7224: Reduce space conditioning during non-working hours | $500 | - | - |
$500
-
MMBtu
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $243 | $251 |
$243
3,810
kWh
|
- | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $910 | $50 |
$910
14,654
kWh
|
- | |
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,280 | - |
$2,280
35,170
kWh
|
- | |
08 | 2.3191: Use demand controller or load shedder | $7,890 | $5,000 |
$7,890
-
kWh
|
- | |
TOTAL RECOMMENDED | $13,221 | $25,849 |
$11,941
63,306
kWh
|
$1,280
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs