Assessment Year | 1984 |
---|---|
Principal Product | AUTO PARTS REMANUFACTURE |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $5 M to 10M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,603 | 529,894 |
kWh
|
$0.082 |
Natural Gas | $19,318 | 3,400 |
MMBtu
|
$5.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,768 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,058 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $470 | $300 |
$238
2,931
kWh
|
$232
-
MMBtu
|
|
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,520 | $1,000 |
$1,520
-
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,015 | $216 |
$1,015
12,309
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $193 | $10,600 |
$193
2,345
kWh
|
- | |
05 | 2.7492: Use proper thickness of insulation on building envelope | $850 | $2,858 | - |
$850
-
MMBtu
|
|
06 | 2.7243: Improve air circulation with destratification fans / other methods | $720 | $1,400 |
$(-40.0)
(-1,172)
kWh
|
$760
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,768 | $16,374 |
$2,926
16,413
kWh
|
$1,842
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,058 | $13,674 |
$1,208
14,654
kWh
|
$850
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs