Assessment Year | 1984 |
---|---|
Principal Product | YARNS & TWINES |
NAICS |
n/a
|
SIC | 2281: Yarn Spinning Mills |
Sales Range | $10 M to 50M |
# of Employees | 215 |
Plant Area |
n/a
|
Annual Production | 6,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $238,073 | 4,711,899 |
kWh
|
$0.051 |
Natural Gas | $17,992 | 3,100 |
MMBtu
|
$5.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,243 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,523 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $12,518 | $12,000 |
$12,518
-
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $2,575 | $2,442 |
$2,575
50,996
kWh
|
- | |
03 | 2.2711: Utilize outside air instead of conditioned air for drying | $1,720 | $4,000 |
$1,720
69,754
kWh
|
- | |
04 | 2.7261: Install timers and/or thermostats | $730 | $1,500 | - |
$730
-
MMBtu
|
|
05 | 2.7492: Use proper thickness of insulation on building envelope | $4,700 | $18,800 |
$4,082
81,770
kWh
|
$618
-
MMBtu
|
|
TOTAL RECOMMENDED | $22,243 | $38,742 |
$20,895
202,520
kWh
|
$1,348
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,523 | $34,742 |
$19,175
132,766
kWh
|
$1,348
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs