| Assessment Year | 1984 |
|---|---|
| Principal Product | CUSTOM VACUUM PLASTICS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $67,132 | 951,641 |
kWh
|
$0.071 |
| Natural Gas | $5,590 | 924 |
MMBtu
|
$6.05 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,418 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,418 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3191: Use demand controller or load shedder | $4,190 | $6,000 |
$4,190
-
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $182 | $207 |
$182
2,638
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $950 | $250 |
$950
13,482
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $886 | $932 |
$886
12,603
kWh
|
- | |
| 05 | 2.8112: Combine utility meters | $210 | $100 | - |
$210
-
MMBtu
|
|
| TOTAL RECOMMENDED | $6,418 | $7,489 |
$6,208
28,723
kWh
|
$210
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,418 | $7,489 |
$6,208
28,723
kWh
|
$210
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs