| Assessment Year | 1984 |
|---|---|
| Principal Product | WOVEN RUGS |
| NAICS |
n/a
|
| SIC | 2273: Carpets and Rugs |
| Sales Range | $10 M to 50M |
| # of Employees | 105 |
| Plant Area |
n/a
|
| Annual Production | 21,500
thousand feet
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $36,875 | 614,889 |
kWh
|
$0.060 |
| Natural Gas | $46,201 | 8,055 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,232 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,232 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1224: Replace boiler | $8,550 | $25,000 | - |
$8,550
-
MMBtu
|
|
| 02 | 2.2135: Repair and eliminate steam leaks | $2,540 | $250 | - |
$2,540
-
MMBtu
|
|
| 03 | 2.2122: Install / repair insulation on condensate lines | $334 | $192 | - |
$334
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,069 | $145 |
$1,069
17,878
kWh
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $739 | $861 |
$739
12,309
kWh
|
- | |
| TOTAL RECOMMENDED | $13,232 | $26,448 |
$1,808
30,187
kWh
|
$11,424
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,232 | $26,448 |
$1,808
30,187
kWh
|
$11,424
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs