Assessment Year | 1983 |
---|---|
Principal Product | BEEF |
NAICS |
n/a
|
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $50 M to 100M |
# of Employees | 208 |
Plant Area |
n/a
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $344,117 | 7,684,936 |
kWh
|
$0.045 |
Natural Gas | $166,585 | 31,632 |
MMBtu
|
$5.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $36,150 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,310 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,089 | $250 | - |
$2,089
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,957 | $4,500 |
$3,957
90,856
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $5,914 | $37,000 |
$5,914
135,991
kWh
|
- | |
04 | 2.3191: Use demand controller or load shedder | $7,310 | $9,000 |
$7,310
-
kWh
|
- | |
05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $8,380 | $12,500 | - |
$8,380
-
MMBtu
|
|
06 | 2.2443: Re-use or recycle hot or cold process exhaust air | $8,500 | $14,000 |
$8,500
195,193
kWh
|
- | |
TOTAL RECOMMENDED | $36,150 | $77,250 |
$25,681
422,040
kWh
|
$10,469
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,310 | $9,000 |
$7,310
-
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs