| Assessment Year | 1983 |
|---|---|
| Principal Product | CARPET TILES |
| NAICS |
n/a
|
| SIC | 2399: Fabricated Textile Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 3,600,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $327,642 | 8,283,412 |
kWh
|
$0.040 |
| Natural Gas | $80,365 | 13,870 |
MMBtu
|
$5.79 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,527 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,700 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,680 | $8,960 |
$3,680
93,200
kWh
|
- | |
| 02 | 2.3191: Use demand controller or load shedder | $6,513 | $9,000 |
$6,513
-
kWh
|
- | |
| 03 | 2.7229: Air condition only space necessary | $1,040 | $400 |
$1,040
26,377
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $1,357 | $7,400 |
$1,357
34,291
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,237 | $2,380 |
$1,237
31,360
kWh
|
- | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $2,700 | $4,500 | - |
$2,700
-
MMBtu
|
|
| TOTAL RECOMMENDED | $16,527 | $32,640 |
$13,827
185,228
kWh
|
$2,700
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $2,700 | $4,500 | - |
$2,700
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs