| Assessment Year | 1982 |
|---|---|
| Principal Product | CANNED PIMENTOS, BEANS |
| NAICS |
n/a
|
| SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
| Sales Range | $10 M to 50M |
| # of Employees | 375 |
| Plant Area |
n/a
|
| Annual Production | 1,500,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $87,978 | 2,674,091 |
kWh
|
$0.033 |
| Natural Gas | $325,253 | 91,270 |
MMBtu
|
$3.56 |
| Fuel Oil #2 | $23,999 | 3,709 |
MMBtu
|
$6.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $29,135 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $383 | $881 |
$383
11,723
kWh
|
- | - | |
| 02 | 2.2136: Install / repair insulation on steam lines | $741 | $618 | - |
$741
-
MMBtu
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $3,641 | $102,476 |
$3,641
110,492
kWh
|
- | - | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $18,522 | $500 | - |
$17,249
-
MMBtu
|
$1,273
-
MMBtu
|
|
| 05 | 2.1232: Keep boiler tubes clean | $5,848 | $5,000 | - |
$5,447
-
MMBtu
|
$401
-
MMBtu
|
|
| TOTAL RECOMMENDED | $29,135 | $109,475 |
$4,024
122,215
kWh
|
$23,437
-
MMBtu
|
$1,674
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs