Assessment Year | 1982 |
---|---|
Principal Product | DOORS/WINDOWS-FRAMES |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $5 M to 10M |
# of Employees | 45 |
Plant Area |
n/a
|
Annual Production | 70,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $15,554 | 244,725 |
kWh
|
$0.064 |
Natural Gas | $1,815 | 455 |
MMBtu
|
$3.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,386 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,195 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $971 | - |
$971
15,240
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $191 | $434 |
$191
2,931
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,559 | - |
$1,559
24,619
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $665 | $50 |
$665
10,551
kWh
|
|
TOTAL RECOMMENDED | $3,386 | $484 |
$3,386
53,341
kWh
|
||
TOTAL IMPLEMENTED | $3,195 | $50 |
$3,195
50,410
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs