| Assessment Year | 1982 |
|---|---|
| Principal Product | PAINTS |
| NAICS |
n/a
|
| SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
n/a
|
| Annual Production | 1,000
Tgal
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $37,551 | 512,896 |
kWh
|
$0.073 |
| Natural Gas | $20,820 | 4,902 |
MMBtu
|
$4.25 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,814 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $330 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $1,584 | $560 |
$(-558.0)
(-7,620)
kWh
|
$2,142
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $1,900 | $2,039 |
$1,900
26,084
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $330 | $304 |
$330
4,396
kWh
|
- | |
| TOTAL RECOMMENDED | $3,814 | $2,903 |
$1,672
22,860
kWh
|
$2,142
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $330 | $304 |
$330
4,396
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs