Assessment Year | 1982 |
---|---|
Principal Product | MEN'S PANTS |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $10 M to 50M |
# of Employees | 210 |
Plant Area |
n/a
|
Annual Production | 159,600
pieces
|
Production Hrs. Annual | 1,960
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $32,668 | 837,339 |
kWh
|
$0.039 |
Natural Gas | $26,592 | 8,742 |
MMBtu
|
$3.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,518 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,518 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $8,931 | $1,900 | - |
$8,931
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,067 | $400 |
$4,067
104,338
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,124 | $6,215 |
$4,124
105,803
kWh
|
- | |
04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $648 | - |
$648
16,706
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $748 | $359 |
$748
19,050
kWh
|
- | |
TOTAL RECOMMENDED | $18,518 | $8,874 |
$9,587
245,897
kWh
|
$8,931
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,518 | $8,874 |
$9,587
245,897
kWh
|
$8,931
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs