Assessment Year | 1998 |
---|---|
Principal Product | Construction and Maintenance Vehicles |
NAICS |
n/a
|
SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
54,000
ft2
|
Annual Production | 180
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $21,672 | 699,297 |
kWh
|
$0.031 |
Electricity Demand | $17,628 | 2,328 |
kW-mo/yr
|
$7.57 |
Electricity Fees | $1,665 | - |
|
- |
Natural Gas | $12,712 | 3,611 |
MMBtu
|
$3.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,073 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,172 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,348 | $4,800 |
$1,232
39,859
kWh
|
$1,116
-
kW-mo/yr
|
- | - | - | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $602 | $180 |
$284
9,086
kWh
|
$318
-
kW-mo/yr
|
- | - | - | - | - | - | |
03 | 2.3212: Optimize plant power factor | $438 | $985 | - | - | $438 | - | - | - | - | - | |
04 | 3.1192: Reduce scrap production | $3,270 | $172 | - | - | - | - |
$3,270
-
lb
|
- | - | - | |
05 | 3.4115: Recover and reuse cooling water | $875 | $1,023 | - | - | - |
$476
-
Tgal
|
- | - | - |
$399
-
Tgal
|
|
06 | 4.711: Initiate a total quality management program | $4,588 | $3,000 | - | - | - | - | - | - | $4,588 | - | |
07 | 2.6124: Establish equipment maintenance schedule | $952 | $1,695 | - | - | - | - | - | $952 | - | - | |
TOTAL RECOMMENDED | $13,073 | $11,855 |
$1,516
48,945
kWh
|
$1,434
-
kW-mo/yr
|
$438 |
$476
-
Tgal
|
$3,270
-
lb
|
$952 | $4,588 |
$399
-
Tgal
|
||
TOTAL IMPLEMENTED | $7,172 | $6,847 |
$1,516
48,945
kWh
|
$1,434
-
kW-mo/yr
|
- | - |
$3,270
-
lb
|
$952 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs