Assessment Year | 1996 |
---|---|
Principal Product | Industrial Ovens and Furnaces |
NAICS |
n/a
|
SIC | 3156: |
Sales Range | $10 M to 50M |
# of Employees | 220 |
Plant Area |
148,800
ft2
|
Annual Production | 208
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,658 | 3,925,557 |
kWh
|
$0.031 |
Electricity Demand | $78,976 | 10,548 |
kW-mo/yr
|
$7.49 |
Electricity Fees | $7,342 | - |
|
- |
Natural Gas | $92,177 | 42,104 |
MMBtu
|
$2.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,068 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $75,068 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,466 | $14,848 |
$7,794
236,225
kWh
|
$5,672
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $168 | $1,484 |
$96
2,931
kWh
|
$72
-
kW-mo/yr
|
- | - | - | |
03 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $57,080 | $6,500 | - | - | - |
$55,120
-
gal
|
$1,960
-
lb
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $336 | $240 |
$336
10,258
kWh
|
- | - | - | - | |
05 | 2.7261: Install timers and/or thermostats | $4,018 | $2,250 | - | - |
$4,018
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $75,068 | $25,322 |
$8,226
249,414
kWh
|
$5,744
-
kW-mo/yr
|
$4,018
-
MMBtu
|
$55,120
-
gal
|
$1,960
-
lb
|
||
TOTAL IMPLEMENTED | $75,068 | $25,322 |
$8,226
249,414
kWh
|
$5,744
-
kW-mo/yr
|
$4,018
-
MMBtu
|
$55,120
-
gal
|
$1,960
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs