Assessment Year | 1996 |
---|---|
Principal Product | Crop Shredders, Snow Blowers, Rock Pickers |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
70,000
ft2
|
Annual Production | 2,590
pieces
|
Production Hrs. Annual | 2,385
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $14,384 | 464,244 |
kWh
|
$0.031 |
Electricity Demand | $20,452 | 2,764 |
kW-mo/yr
|
$7.40 |
Electricity Fees | $1,781 | - |
|
- |
Natural Gas | $16,778 | 3,583 |
MMBtu
|
$4.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,541 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,707 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $868 | $2,959 |
$244
7,913
kWh
|
$624
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,518 | $12,579 |
$1,144
36,928
kWh
|
$1,374
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.3212: Optimize plant power factor | $1,316 | $2,150 | - | - | - | - | - | $1,316 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,395 | $260 |
$871
28,136
kWh
|
$524
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.2121: Convert to electrostatic powder coating | $17,650 | $6,080 | - | - | - | - | $17,650 | - | |
06 | 2.7224: Reduce space conditioning during non-working hours | $3,029 | $2,400 | - | - |
$3,029
-
MMBtu
|
- | - | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,765 | $4,750 | - | - | - |
$2,765
-
lb
|
- | - | |
TOTAL RECOMMENDED | $29,541 | $31,178 |
$2,259
72,977
kWh
|
$2,522
-
kW-mo/yr
|
$3,029
-
MMBtu
|
$2,765
-
lb
|
$17,650 | $1,316 | ||
TOTAL IMPLEMENTED | $25,707 | $16,449 |
$1,115
36,049
kWh
|
$1,148
-
kW-mo/yr
|
$3,029
-
MMBtu
|
$2,765
-
lb
|
$17,650 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs