Assessment Year | 1996 |
---|---|
Principal Product | Plating Metal Parts |
NAICS |
n/a
|
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $1 M to 5M |
# of Employees | 37 |
Plant Area |
19,652
ft2
|
Annual Production | 600,000
pieces
|
Production Hrs. Annual | 2,470
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,128 | 843,200 |
kWh
|
$0.037 |
Electricity Demand | $11,088 | 3,036 |
kW-mo/yr
|
$3.65 |
Electricity Fees | $377 | - |
|
- |
Natural Gas | $11,801 | 3,565 |
MMBtu
|
$3.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,329 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,940 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $305 | $1,149 |
$200
5,275
kWh
|
$105
-
kW-mo/yr
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $1,084 | $3,765 |
$647
17,585
kWh
|
$437
-
kW-mo/yr
|
- | |
03 | 2.2511: Insulate bare equipment | $1,434 | $1,257 |
$1,434
38,687
kWh
|
- | - | |
04 | 3.4113: Treat and reuse rinse waters | $8,506 | $17,190 |
$(-239.0)
(-6,448)
kWh
|
$(-145.0)
-
kW-mo/yr
|
$8,890
-
Tgal
|
|
TOTAL RECOMMENDED | $11,329 | $23,361 |
$2,042
55,099
kWh
|
$397
-
kW-mo/yr
|
$8,890
-
Tgal
|
||
TOTAL IMPLEMENTED | $9,940 | $18,447 |
$1,195
32,239
kWh
|
$(-145.0)
-
kW-mo/yr
|
$8,890
-
Tgal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs