Assessment Year | 1994 |
---|---|
Principal Product | Induction & Synchronous Motors and Generators |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $50 M to 100M |
# of Employees | 352 |
Plant Area |
310,000
ft2
|
Annual Production | 175
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $302,490 | 8,531,946 |
kWh
|
$0.035 |
Natural Gas | $167,925 | 41,340 |
MMBtu
|
$4.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,139 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,811 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,963 | $38,850 |
$17,963
309,789
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $4,546 | $14,287 |
$4,546
78,253
kWh
|
- | |
03 | 2.4131: Size electric motors for peak operating efficiency | $7,302 | $1,499 |
$7,302
126,026
kWh
|
- | |
04 | 2.7231: Use radiant heater for spot heating | $19,328 | $51,600 | - |
$19,328
-
MMBtu
|
|
TOTAL RECOMMENDED | $49,139 | $106,236 |
$29,811
514,068
kWh
|
$19,328
-
MMBtu
|
||
TOTAL IMPLEMENTED | $29,811 | $54,636 |
$29,811
514,068
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs