Assessment Year | 2024 |
---|---|
Principal Product | Composite aerospace parts |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 56 |
Plant Area |
70,000
ft2
|
Annual Production | 1,500
units
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | Maryland |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $210,226 | 1,371,814 |
kWh
|
$0.15 |
Electricity Demand | $19,772 | 4,339 |
kW-mo/yr
|
$4.56 |
Electricity Fees | $1,164 | - |
|
- |
Natural Gas | $25,487 | 2,086 |
MMBtu
|
$12.22 |
TOTAL YEARLY COSTS | $256,649 | |||
RECOMMENDED SAVINGS* | $36,204 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $7,341 | - |
$6,686
43,698
kWh
|
$655
-
kW-mo/yr
|
- | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $9,667 | - |
$8,804
57,541
kWh
|
$863
-
kW-mo/yr
|
- | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $5,998 | - |
$4,128
26,978
kWh
|
$404
-
kW-mo/yr
|
$1,466
-
MMBtu
|
|
04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $1,180 | $64 |
$1,074
7,021
kWh
|
$106
-
kW-mo/yr
|
- | |
05 | 2.7314: Reduce ventilation air | $1,145 | $270 |
$416
2,721
kWh
|
$41
-
kW-mo/yr
|
$688
-
MMBtu
|
|
06 | 2.2437: Recover waste heat from equipment | $3,985 | $4,000 |
$3,629
23,722
kWh
|
$356
-
kW-mo/yr
|
- | |
07 | 2.7313: Recycle air for heating, ventilation and air conditioning | $682 | $4,000 |
$621
4,062
kWh
|
$61
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $333 | $252 |
$303
1,979
kWh
|
$30
-
kW-mo/yr
|
- | |
09 | 2.7232: Replace existing hvac unit with high efficiency model | $5,873 | $30,027 |
$5,348
34,956
kWh
|
$525
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $36,204 | $38,613 |
$31,009
202,678
kWh
|
$3,041
-
kW-mo/yr
|
$2,154
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs