| Assessment Year | 2024 |
|---|---|
| Principal Product | Gypsum Drywall |
| NAICS | 327420: Gypsum Product Manufacturing |
| SIC | 3275: Gypsum Products |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
200,000
ft2
|
| Annual Production | 345,000
ton
|
| Production Hrs. Annual | 8,060
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,505,328 | 19,725,456 |
kWh
|
$0.13 |
| Electricity Demand | $41,005 | 34,608 |
kW-mo/yr
|
$1.18 |
| Electricity Fees | $24,456 | - |
|
- |
| Natural Gas | $4,500,127 | 738,908 |
MMBtu
|
$6.09 |
| TOTAL YEARLY COSTS | $7,070,916 | |||
| RECOMMENDED SAVINGS* | $230,401 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2522: Isolate hot or cold equipment | $36,400 | $82,500 |
$36,400
280,000
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $21,550 | $30,000 |
$21,550
165,800
kWh
|
- | |
| 03 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $95,717 | $35,600 | - |
$95,717
-
MMBtu
|
|
| 04 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $76,734 | $166,100 | - |
$76,734
-
MMBtu
|
|
| TOTAL RECOMMENDED | $230,401 | $314,200 |
$57,950
445,800
kWh
|
$172,451
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs