ITAC Assessment: DL0186
ITAC logo
ITAC Assessment: DL0186
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product Lighting Fixtures
NAICS 335121: Residential Electric Lighting Fixture Manufacturing
SIC 3645: Residential Electric Lighting Fixtures
Sales Range $1
M
to 5
M
# of Employees 23
Plant Area 28,000
ft2
Annual Production 10,000
units
Production Hrs. Annual 3,000
hrs
Location (State) Delaware

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $10,425 201,513
kWh
Electricity Demand $10,403 906
kW-mo/yr
Electricity Fees $900 -
Natural Gas $20,120 2,302
MMBtu
Waste Disposal Costs
Water Usage $2,789 612
Tgal
TOTAL YEARLY COSTS $44,637
RECOMMENDED SAVINGS* $21,329 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,512

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings
01 2.6218: Turn off equipment when not in use $5,690 - - - $5,690
-
MMBtu
-
02 2.6218: Turn off equipment when not in use $2,738 - $1,306
25,120
kWh
- $1,432
-
MMBtu
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,598 $6,500 $800
15,380
kWh
$967
-
kW-mo/yr
$831
-
MMBtu
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $773 $799 $606
11,660
kWh
$167
-
kW-mo/yr
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $875 $3,275 $448
8,615
kWh
$427
-
kW-mo/yr
- -
06 3.4154: Eliminate leaks in water lines and valves $2,060 $1,500 $1,140
21,915
kWh
$344
-
kW-mo/yr
- $576
-
Tgal
07 2.6212: Turn off equipment during breaks, reduce operating time $182 - $88
1,680
kWh
$94
-
kW-mo/yr
- -
08 2.2135: Repair and eliminate steam leaks $2,190 $3,000 - - $2,190
-
MMBtu
-
09 2.1224: Replace boiler $2,104 $7,098 - - $2,104
-
MMBtu
-
10 2.7224: Reduce space conditioning during non-working hours $1,852 - - - $1,852
-
MMBtu
-
11 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $115 - $88
1,690
kWh
$27
-
kW-mo/yr
- -
12 2.1121: Use insulation in furnaces to facilitate heating / cooling $152 $400 - - $152
-
MMBtu
-
TOTAL RECOMMENDED $21,329 $22,572 $4,476
86,060
kWh
$2,026
-
kW-mo/yr
$14,251
-
MMBtu
$576
-
Tgal
TOTAL IMPLEMENTED $16,512 $8,974 $3,588
68,990
kWh
$1,032
-
kW-mo/yr
$11,316
-
MMBtu
$576
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs