ITAC Assessment: DL0167
ITAC logo
ITAC Assessment: DL0167
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Textiles
NAICS 315210: Cut and Sew Apparel Contractors
SIC 2395: Pleating, Decorative and Novelty Stitching, and Tucking for the Trade
Sales Range $10
M
to 50
M
# of Employees 90
Plant Area 60,000
ft2
Annual Production 130,000
pieces
Production Hrs. Annual 5,902
hrs
Location (State) Delaware

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $189,432 2,808,960
kWh
Electricity Demand $122,820 6,861
kW-mo/yr
Electricity Fees $13,896 -
Natural Gas $268,209 47,631
MMBtu
Waste Disposal Costs
Water Usage $214,071 30,581
Tgal
Water Disposal $92,880 17,525
Tgal
TOTAL YEARLY COSTS $901,308
RECOMMENDED SAVINGS* $118,177 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $54,362

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2437: Recover waste heat from equipment $4,099 $4,200 - - $4,099
-
MMBtu
02 2.7142: Utilize higher efficiency lamps and/or ballasts $11,895 $16,550 $7,706
115,020
kWh
$4,189
-
kW-mo/yr
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,405 $3,610 $1,564
23,350
kWh
$841
-
kW-mo/yr
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,603 $5,470 $1,225
18,290
kWh
$1,378
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $6,000 $13,010 $2,688
40,115
kWh
$3,312
-
kW-mo/yr
-
06 2.2414: Use waste heat from hot flue gases to preheat $8,529 $21,200 - - $8,529
-
MMBtu
07 2.2449: Recover heat from exhausted steam, hot air or hot water $33,048 $85,000 - - $33,048
-
MMBtu
08 2.2437: Recover waste heat from equipment $40,226 $107,360 - - $40,226
-
MMBtu
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,556 $36,400 $5,549
82,820
kWh
$3,007
-
kW-mo/yr
-
10 2.2449: Recover heat from exhausted steam, hot air or hot water $816 $4,560 - - $816
-
MMBtu
TOTAL RECOMMENDED $118,177 $297,360 $18,732
279,595
kWh
$12,727
-
kW-mo/yr
$86,718
-
MMBtu
TOTAL IMPLEMENTED $54,362 $124,590 $11,619
173,425
kWh
$8,879
-
kW-mo/yr
$33,864
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs