| Assessment Year | 2016 |
|---|---|
| Principal Product | Analytical Equipment |
| NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
| SIC | 3826: Laboratory Analytical Instruments |
| Sales Range | $50 M to 100M |
| # of Employees | 400 |
| Plant Area |
365,000
ft2
|
| Annual Production | 5,000
pieces
|
| Production Hrs. Annual | 5,356
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,353,527 | 14,946,454 |
kWh
|
$0.091 |
| Natural Gas | $90,727 | 10,486 |
MMBtu
|
$8.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $127,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,485 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $25,680 | - |
$18,890
207,560
kWh
|
$6,790
-
MMBtu
|
|
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,550 | - |
$2,550
28,050
kWh
|
- | |
| 03 | 2.7314: Reduce ventilation air | $32,810 | $1,560 |
$21,390
235,070
kWh
|
$11,420
-
MMBtu
|
|
| 04 | 2.2437: Recover waste heat from equipment | $18,520 | $65,650 |
$11,560
127,000
kWh
|
$6,960
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $21,525 | $99,395 |
$21,525
236,545
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,935 | $211,395 |
$25,935
284,990
kWh
|
- | |
| TOTAL RECOMMENDED | $127,020 | $378,000 |
$101,850
1,119,215
kWh
|
$25,170
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $28,485 | $211,395 |
$28,485
313,040
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs