| Assessment Year | 2015 |
|---|---|
| Principal Product | Architectural Glass |
| NAICS | 327211: Flat Glass Manufacturing |
| SIC | 3211: Flat Glass |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
108,000
ft2
|
| Annual Production | 2,000,000
lb
|
| Production Hrs. Annual | 2,700
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $73,534 | 1,210,193 |
kWh
|
$0.061 |
| Electricity Demand | $42,287 | 7,120 |
kW-mo/yr
|
$5.94 |
| Natural Gas | $10,378 | 1,227 |
MMBtu
|
$8.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,315 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,190 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,690 | - |
$550
5,305
kWh
|
- |
$3,140
-
MMBtu
|
|
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $500 | - |
$500
4,875
kWh
|
- | - | |
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $8,960 | $6,880 |
$8,960
87,010
kWh
|
- | - | |
| 04 | 2.7424: Shade windows from summer sun | $1,760 | $6,840 |
$1,760
17,100
kWh
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,405 | $13,615 |
$2,710
26,270
kWh
|
$695
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $18,315 | $27,335 |
$14,480
140,560
kWh
|
$695
-
kW-mo/yr
|
$3,140
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,190 | - |
$1,050
10,180
kWh
|
- |
$3,140
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs