Assessment Year | 2015 |
---|---|
Principal Product | Flat Rolled Steel |
NAICS | 331110: Iron and Steel Mills and Ferroalloy Manufacturing |
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 67 |
Plant Area |
140,000
ft2
|
Annual Production | 150,000
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $169,981 | 2,024,400 |
kWh
|
$0.084 |
Natural Gas | $68,421 | 5,708 |
MMBtu
|
$11.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,630 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,610 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $6,880 | $1,000 |
$6,880
81,900
kWh
|
|
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $730 | $100 |
$730
8,730
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $500 | $1,425 |
$500
5,990
kWh
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $27,520 | $125,000 |
$27,520
327,600
kWh
|
|
TOTAL RECOMMENDED | $35,630 | $127,525 |
$35,630
424,220
kWh
|
||
TOTAL IMPLEMENTED | $7,610 | $1,100 |
$7,610
90,630
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs