ITAC Assessment: DL0137
ITAC logo
ITAC Assessment: DL0137
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2014
Principal Product Beer and Soda
NAICS 312120: Breweries
SIC 2082: Malt Beverages
Sales Range $5
M
to 10
M
# of Employees 30
Plant Area 19,100
ft2
Annual Production 35,000
bbl
Production Hrs. Annual 4,056
hrs
Location (State) Delaware

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $76,383 680,560
kWh
Natural Gas $59,606 8,870
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $47,510 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,510

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
01 2.2121: Increase amount of condensate returned $17,190 $20,000 - $7,800
-
MMBtu
$6,280
-
Tgal
$3,110
-
Tgal
02 2.4235: Remove or close off unneeded compressed air lines $14,240 $5,460 $14,240
127,170
kWh
- - -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,900 $38,400 $5,900
52,730
kWh
- - -
04 2.2441: Preheat boiler makeup water with waste process heat $890 $2,220 - $890
-
MMBtu
- -
05 2.2437: Recover waste heat from equipment $1,520 $8,430 $500
4,460
kWh
$1,020
-
MMBtu
- -
06 2.2511: Insulate bare equipment $745 $160 - $745
-
MMBtu
- -
07 2.2136: Install / repair insulation on steam lines $2,350 $6,300 - $2,350
-
MMBtu
- -
08 2.2136: Install / repair insulation on steam lines $970 $1,200 - $970
-
MMBtu
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $245 $2,280 $245
2,195
kWh
- - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $2,820 $10,075 $2,820
25,200
kWh
- - -
11 2.7142: Utilize higher efficiency lamps and/or ballasts $640 $1,040 $640
5,710
kWh
- - -
TOTAL RECOMMENDED $47,510 $95,565 $24,345
217,465
kWh
$13,775
-
MMBtu
$6,280
-
Tgal
$3,110
-
Tgal
TOTAL IMPLEMENTED $20,510 $27,500 - $11,120
-
MMBtu
$6,280
-
Tgal
$3,110
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs