| Assessment Year | 2014 |
|---|---|
| Principal Product | Clothing |
| NAICS | 315280: Other Cut and Sew Apparel Manufacturing |
| SIC | 2389: Apparel and Accessories, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 69 |
| Plant Area |
40,000
ft2
|
| Annual Production | 83,000
pieces
|
| Production Hrs. Annual | 2,856
hrs
|
| Location (State) | Maryland |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $56,549 | 509,000 |
kWh
|
$0.11 |
| Natural Gas | $101,040 | 17,623 |
MMBtu
|
$5.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $56,480 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,970 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $10,900 | $8,500 | - |
$10,900
-
MMBtu
|
- | |
| 02 | 3.4113: Treat and reuse rinse waters | $13,430 | $24,000 | - |
$6,600
-
MMBtu
|
$6,830
-
gal
|
|
| 03 | 2.2437: Recover waste heat from equipment | $20,280 | $40,560 | - |
$20,280
-
MMBtu
|
- | |
| 04 | 2.1123: Install automatic stack damper | $1,840 | $2,800 | - |
$1,840
-
MMBtu
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,260 | $17,852 |
$6,260
56,400
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $520 | $1,910 |
$520
4,690
kWh
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $850 | $200 |
$850
7,670
kWh
|
- | - | |
| 08 | 2.2437: Recover waste heat from equipment | $430 | $1,400 | - |
$430
-
MMBtu
|
- | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,970 | $700 |
$1,970
17,750
kWh
|
- | - | |
| TOTAL RECOMMENDED | $56,480 | $97,922 |
$9,600
86,510
kWh
|
$40,050
-
MMBtu
|
$6,830
-
gal
|
||
| TOTAL IMPLEMENTED | $1,970 | $700 |
$1,970
17,750
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs