Assessment Year 2013
Principal Product vinyl windows and sliding doors
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3999: Manufacturing Industries, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 120
Plant Area 120,000
ft2
Annual Production 70,000
pieces
Production Hrs. Annual 2,350
hrs
Location (State) Delaware

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $102,678 1,060,151
kWh
Electricity Demand $2,189 574
kW-mo/yr
Electricity Fees $5,479 -
Natural Gas $11,796 949
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $34,481 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $23,116

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Water Disposal Savings
01 2.6218: Turn off equipment when not in use $5,567 $100 $5,567
57,396
kWh
-
02 2.6212: Turn off equipment during breaks, reduce operating time $7,275 - $7,275
75,000
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,698 $3,500 $1,698
17,500
kWh
-
04 2.4131: Size electric motors for peak operating efficiency $1,094 $2,000 $1,094
11,280
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $10,271 $49,280 $10,271
105,600
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,455 $20,000 $1,455
15,040
kWh
-
07 3.4113: Treat and reuse rinse waters $7,121 $10,000 $127
1,312
kWh
$6,994
-
Tgal
TOTAL RECOMMENDED $34,481 $84,880 $27,487
283,128
kWh
$6,994
-
Tgal
TOTAL IMPLEMENTED $23,116 $33,600 $16,122
166,248
kWh
$6,994
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs