| Assessment Year | 2012 |
|---|---|
| Principal Product | Heterocyclic Hydrocarbons |
| NAICS | 325199: All Other Basic Organic Chemical Manufacturing |
| SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
| Sales Range | $500 k to 1M |
| # of Employees | 35 |
| Plant Area |
20,000
ft2
|
| Annual Production | 220
lb
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | Delaware |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $135,625 | 1,144,465 |
kWh
|
$0.12 |
| Natural Gas | $83,435 | 6,550 |
MMBtu
|
$12.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $89,708 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,357 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $64,179 | $280,000 |
$32,844
276,000
kWh
|
$31,335
-
MMBtu
|
|
| 02 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $18,536 | $46,000 |
$3,887
32,667
kWh
|
$14,649
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,641 | $1,330 |
$4,641
39,000
kWh
|
- | |
| 04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $716 | $90 |
$716
6,000
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,636 | $2,100 |
$1,636
13,750
kWh
|
- | |
| TOTAL RECOMMENDED | $89,708 | $329,520 |
$43,724
367,417
kWh
|
$45,984
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,357 | $1,420 |
$5,357
45,000
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs