| Assessment Year | 2011 | 
|---|---|
| Principal Product | DPP and QA Crude pigments | 
| NAICS | 325130: Synthetic Dye and Pigment Manufacturing | 
| SIC | 2865: Cyclic Organic Crudes and Intermediates, and Organic Dyes and Pigments | 
| Sales Range | $50 M  to 100M  | 
    
| # of Employees | 26 | 
| Plant Area | 
                            91,200
                 
ft2
 
                     | 
    
| Annual Production | 2,550
             
ton
 
         | 
    
| Production Hrs. Annual | 8,760
             
hrs
 
         | 
    
| Location (State) | Delaware | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,486,707 | 22,094,558 | 
             
kWh
 
         | 
        $0.067 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $146,050 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $72,500 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | 
|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $63,000 | $100 | 
                        $63,000
                                                     940,980
                                 
                                            
kWh
 
                             | 
                                    |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $30,650 | $24,000 | 
                        $30,650
                                                     457,450
                                 
                                            
kWh
 
                             | 
                                    |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,500 | $4,000 | 
                        $9,500
                                                     142,000
                                 
                                            
kWh
 
                             | 
                                    |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $42,900 | $380,000 | 
                        $42,900
                                                     640,000
                                 
                                            
kWh
 
                             | 
                                    |
| TOTAL RECOMMENDED | $146,050 | $408,100 | 
                        $146,050
                                                     2,180,430
                                 
                                            
kWh
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $72,500 | $4,100 | 
                        $72,500
                                                     1,082,980
                                 
                                            
kWh
 
                             | 
                                    ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs