Assessment Year | 2011 |
---|---|
Principal Product | Automobiles |
NAICS | 336111: Automobile Manufacturing |
SIC | 3711: Motor Vehicles and Passenger Car Bodies |
Sales Range | less than $500 k |
# of Employees | 30 |
Plant Area |
1,800,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,800,000 | 60,000,000 |
kWh
|
$0.080 |
Natural Gas | $3,150,000 | 260,000 |
MMBtu
|
$12.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,343,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $904,000 | $2,850,000 |
$1,140,000
14,300,000
kWh
|
$(-236,000.0)
-
MMBtu
|
|
02 | 2.1224: Replace boiler | $420,000 | $408,000 | - |
$420,000
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $19,700 | $6,400 |
$19,700
246,000
kWh
|
- | |
TOTAL RECOMMENDED | $1,343,700 | $3,264,400 |
$1,159,700
14,546,000
kWh
|
$184,000
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs