Assessment Year | 2011 |
---|---|
Principal Product | Thermal Analyzers |
NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | $100 M to 500M |
# of Employees | 109 |
Plant Area |
170,640
ft2
|
Annual Production | 1,800
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $336,700 | 3,318,700 |
kWh
|
$0.10 |
Electricity Demand | $9,857 | 568 |
kW-mo/yr
|
$17.35 |
Electricity Fees | $17,100 | - |
|
- |
Natural Gas | $26,000 | 1,776 |
MMBtu
|
$14.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,381 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7144: Install spectral reflectors / delamp | $5,600 | $3,500 |
$4,400
50,825
kWh
|
$1,200
-
kW-mo/yr
|
- | |
02 | 2.6218: Turn off equipment when not in use | $4,300 | $2,600 |
$2,550
30,394
kWh
|
$1,750
-
kW-mo/yr
|
- | |
03 | 2.6211: Conserve energy by efficient use of vending machines | $331 | $780 |
$331
3,942
kWh
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $5,082 | $1,000 | - | - |
$5,082
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $9,000 | $1,500 |
$7,000
82,000
kWh
|
$2,000
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $4,518 | $3,100 |
$3,068
38,846
kWh
|
$1,450
-
kW-mo/yr
|
- | |
07 | 2.6218: Turn off equipment when not in use | $16,400 | $1,200 |
$16,400
282,300
kWh
|
- | - | |
08 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $19,150 | $13,200 |
$1,600
19,000
kWh
|
$550
-
kW-mo/yr
|
$17,000
-
MMBtu
|
|
TOTAL RECOMMENDED | $64,381 | $26,880 |
$35,349
507,307
kWh
|
$6,950
-
kW-mo/yr
|
$22,082
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs