Assessment Year 2010
Principal Product Aircraft Arresting Systems
NAICS 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing
SIC 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 119
Plant Area 125,625
ft2
Annual Production 100,000
pieces
Production Hrs. Annual 3,510
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $131,606 1,693,212
kWh
Electricity Demand $83,987 488
kW-mo/yr
Electricity Fees $5,739 -
Natural Gas $36,512 2,761
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $92,163 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $44,295

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.6218: Turn off equipment when not in use $6,774 - $6,774
86,849
kWh
- -
02 2.6218: Turn off equipment when not in use $4,044 - $1,591
24,000
kWh
- $2,453
-
MMBtu
03 2.7221: Lower temperature during the winter season and vice-versa $2,212 - - - $2,212
-
MMBtu
04 2.7122: Disconnect ballasts $1,481 - $866
11,100
kWh
$615
-
kW-mo/yr
-
05 2.6212: Turn off equipment during breaks, reduce operating time $1,068 - $1,068
13,697
kWh
- -
06 2.2437: Recover waste heat from equipment $4,117 $690 - - $4,117
-
MMBtu
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $30,000 $6,000 $25,500
301,000
kWh
$4,500
-
kW-mo/yr
-
08 2.7135: Install occupancy sensors $3,491 $1,573 $3,491
44,753
kWh
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $4,972 $3,840 $2,907
37,271
kWh
$2,065
-
kW-mo/yr
-
10 2.7142: Utilize higher efficiency lamps and/or ballasts $19,288 $24,000 $11,278
144,585
kWh
$8,010
-
kW-mo/yr
-
11 2.7232: Replace existing hvac unit with high efficiency model $750 $2,800 $595
7,631
kWh
$155
-
kW-mo/yr
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $13,966 $77,940 $8,626
110,596
kWh
$5,340
-
kW-mo/yr
-
TOTAL RECOMMENDED $92,163 $116,843 $62,696
781,482
kWh
$20,685
-
kW-mo/yr
$8,782
-
MMBtu
TOTAL IMPLEMENTED $44,295 $10,373 $37,428
453,930
kWh
$4,655
-
kW-mo/yr
$2,212
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings