| Assessment Year | 2009 |
|---|---|
| Principal Product | Metal Light Gauge Rolling |
| NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
| SIC | 3355: Aluminum Rolling and Drawing, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 113 |
| Plant Area |
99,000
ft2
|
| Annual Production | 27,000
ton
|
| Production Hrs. Annual | 8,430
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,916,740 | 16,962,305 |
kWh
|
$0.11 |
| Natural Gas | $1,458,268 | 102,695 |
MMBtu
|
$14.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $197,803 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $89,460 | $41,150 | - |
$89,460
-
MMBtu
|
|
| 02 | 2.2437: Recover waste heat from equipment | $31,002 | $5,550 | - |
$31,002
-
MMBtu
|
|
| 03 | 2.2437: Recover waste heat from equipment | $21,300 | $575 | - |
$21,300
-
MMBtu
|
|
| 04 | 2.4239: Eliminate or reduce compressed air usage | $12,400 | $950 |
$12,400
110,000
kWh
|
- | |
| 05 | 2.2611: Moderate cooling tower outlet temperature | $6,452 | - |
$6,452
57,093
kWh
|
- | |
| 06 | 2.4131: Size electric motors for peak operating efficiency | $37,189 | $70,000 |
$37,189
329,107
kWh
|
- | |
| TOTAL RECOMMENDED | $197,803 | $118,225 |
$56,041
496,200
kWh
|
$141,762
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs