Assessment Year | 2008 |
---|---|
Principal Product | Flopack Cushioning, Recycled Polystyrene |
NAICS | 326140: Polystyrene Foam Product Manufacturing |
SIC | 3086: Plastics Foam Products |
Sales Range | $10 M to 50M |
# of Employees | 35 |
Plant Area |
35,000
ft2
|
Annual Production | 1,300
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $240,256 | 1,453,920 |
kWh
|
$0.17 |
Natural Gas | $200,810 | 16,520 |
MMBtu
|
$12.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,424 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,600 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $3,600 | - | - |
$3,600
-
MMBtu
|
|
02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $470 | $635 | - |
$470
-
MMBtu
|
|
03 | 2.2136: Install / repair insulation on steam lines | $2,173 | $4,200 | - |
$2,173
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,481 | $12,133 |
$5,481
49,824
kWh
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,500 | $15,000 |
$5,500
50,000
kWh
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $4,200 | $20,000 | - |
$4,200
-
MMBtu
|
|
TOTAL RECOMMENDED | $21,424 | $51,968 |
$10,981
99,824
kWh
|
$10,443
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,600 | - | - |
$3,600
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs